East-west solar panel arrays are now a familiar sight on homes across the South West. Rather than putting every panel on a single south-facing slope, the installation is split across two roof slopes, with one group of panels facing the morning sun and the other facing the afternoon and evening sun. At Solar Cleaning South West, we clean solar panels on domestic and commercial properties throughout Bath, Bristol and the wider South West, and east-west systems raise some specific questions when it comes to dirt and performance.
The main one is simple: if the two halves of the array face different directions, do they get dirty in the same way, and does dirt on one side affect the other? This guide explains how contamination builds up on east-facing and west-facing panels, why uneven soiling matters, how the electrical layout of the system can change the effect of dirt, and what a sensible cleaning approach looks like for a split array.
What Is an East-West Solar Array?
An east-west array is a solar installation where the panels are fitted to two opposing roof slopes. One set faces east and receives the sun from early in the day. The other set faces west and receives the sun later in the afternoon and into the evening.
Many homeowners believe solar panels are only worthwhile if they face due south. While a south-facing roof will often provide the highest annual electricity generation in the UK, east-facing and west-facing installations can still produce useful electricity. East-facing panels typically give stronger morning production, while west-facing panels give stronger afternoon and evening production.
For many households, generating electricity over a longer portion of the day can be more valuable than producing the highest possible peak.
Why the Layout Matters for Cleaning
From a cleaning point of view, an east-west array is effectively two installations on one roof. Each slope sees the sun at different times, dries at different times and can collect dirt in a slightly different pattern, which helps explain why one half of a split array can look noticeably dirtier than the other.
How Dirt Builds Up on East-Facing Panels
East-facing panels receive the morning sun. This means they often dry earlier in the day after overnight dew, mist or light rain.
That early drying is not necessarily a guarantee of cleaner glass. When moisture sits on the panels overnight and then dries in the morning, it can leave behind whatever was carried in it or settled into it. East-facing panels can be prone to a build-up of residue left by morning dew.
Morning Moisture and Residue
When the sun reaches an east-facing slope and overnight moisture evaporates, fine dust and other particles can be left on the surface, and repeated wetting and drying can gradually form a film across the glass.
On foggy mornings, east-facing panels receive early sunlight, which reduces the length of time they stay damp. Even so, fog and mist do not provide meaningful cleaning. Mist can leave mineral deposits as it dries, and damp conditions can allow airborne contamination to remain wet long enough to bond to the glass.
How Dirt Builds Up on West-Facing Panels
West-facing panels follow the opposite pattern. They remain shaded for longer each morning and continue receiving sunshine later into the afternoon and evening.
Because they stay shaded in the early part of the day, west-facing panels often remain damp for longer on foggy or misty mornings. West-facing panels are also associated with afternoon dust accumulation and with pollution and grime collected later in the day.
Late-Day Exposure
West-facing arrays spend the later part of the day in direct sunlight. Any contamination that has settled during the day, such as dust or pollen, is then exposed to that afternoon warmth. Bird droppings and sticky deposits can dry and harden onto the glass, making them more difficult for rain to shift.
West-facing panels also tend to stay warmer later into the afternoon, and solar panels do not cool immediately when direct sunlight disappears. This affects the safest time to clean them.
Prevailing Winds
East-facing and west-facing roof slopes can also experience uneven dirt build-up depending on prevailing winds. Wind carries dust, pollen, agricultural residue, salt and other particles, and one side of a roof can catch more of this than the other. On a split array, that can be enough to make one slope visibly dirtier.
Why Uneven Soiling Matters
When dirt is spread fairly evenly across an entire array, the effect is mainly a gradual reduction in the amount of sunlight reaching the photovoltaic cells. Uneven soiling is different.
Orientation-related variations in dirt can lead to uneven soiling across a single roof, which can contribute to performance imbalance. An east-west array has a built-in tendency towards this, because the two slopes are exposed to different conditions every day.
Localised Shading From Dirt
Some types of contamination block sunlight far more than others. Light dust causes a small reduction across the surface. Pollen forms a more even coating that gradually reduces efficiency. Bird droppings, on the other hand, cause severe localised shading, while moss residue and lichen can create dense shading around panel edges and stubborn deposits over active cells.
A single bird dropping positioned over several cells can reduce the performance of a much larger section of a panel. This is because solar cells are connected together electrically, so a shaded section can affect more than just the cells directly underneath it.
Shading and Dirt Combined
The biggest performance losses often occur when permanent shading combines with dirt accumulation. Many roofs have some unavoidable shade from a chimney, a TV aerial, a dormer, a neighbouring building or a tree.
On an east-west roof, that shade usually falls on one slope at a particular time of day. A chimney might shade the corner of an east-facing panel early in the morning, while a nearby tree might shade the west-facing slope later in the afternoon. If dirt has already accumulated in those same areas, the combination of moving shadows and surface contamination can reduce generation at more than one point during the day.
Hotspots
When a solar cell is shaded by dirt or debris and produces less electricity, it can begin generating heat instead. This is known as a hotspot. Hotspots increase temperatures within individual cells and may contribute to reduced efficiency, cell degradation and, over time, permanent damage.
You can read more about this in our guide to whether dirty solar panels can cause hot spots.
How the Electrical Layout Changes the Effect of Dirt
The way an east-west array is wired has a big influence on how dirt on one slope affects the rest of the system. Every installation is different, so the exact configuration of your system will depend on how it was designed.
Traditional String Systems
In a traditional string system, several panels are connected together in series. The same current passes through each panel in the string, and the current is influenced by the panel producing the weakest available output under the prevailing conditions.
That means one heavily shaded or soiled panel can restrict the performance of its string to some degree. It does not mean every panel in the string has stopped working. Instead, the electrical characteristics of the string can cause the overall output to be constrained.
Microinverters
Systems using microinverters work differently. A microinverter is associated with an individual panel, so the performance of one dirty panel is generally more isolated from the others. If one panel becomes heavily soiled, the other panels can continue operating independently.
That does not make cleaning unnecessary. The dirty panel can still lose a significant amount of its own potential generation, and if several panels become dirty, the cumulative loss can become substantial.
Power Optimisers
Power optimisers work at panel level and can help manage differences in performance between individual panels. This can be particularly useful where a roof has unavoidable shading or where panels face different directions, which is exactly the situation on an east-west array.
However, optimisers do not restore electricity that is not being generated because sunlight is blocked. If a dirty panel cannot receive enough sunlight, it still cannot produce the same amount of energy as a clean panel receiving full sunlight. For a closer look at these differences, see our article on string inverters vs microinverters and how dirt affects them.
How Much Output Can Dirt Take From an East-West Array?
There is no single figure that applies to every installation, and claims about cleaning producing a specific percentage increase should be treated cautiously.
The effect of dirt depends on several factors, including:
- The type of contamination and how heavy it is
- Where the dirt is positioned on each panel
- How the panels are electrically connected
- Existing shading from chimneys, trees or neighbouring buildings
- Weather and sunlight levels
- The orientation and pitch of each slope
A lightly dusty array is very different from one with bird droppings, pollen and accumulated grime. A lightly dusty panel may see a relatively modest improvement from cleaning, while heavily contaminated panels can benefit considerably more.
Cleaning should not be viewed as a way to increase a panel’s output beyond its design capability. Instead, it helps restore the panel closer to the performance it should achieve under the available conditions.
Why Morning or Evening Output May Drop First
Because each slope generates at a different time of day, dirt on an east-west array can show up as a change in a particular part of the day rather than across the whole day. Heavy contamination on the east-facing slope may affect morning generation, while dirt on the west-facing slope may affect afternoon and evening generation.
This is not a fixed rule, but it is worth keeping in mind if your monitoring shows one part of the day consistently underperforming compared with similar weather in previous periods.
Spotting Dirt on a Split Array
A solar array can look relatively clean from ground level while individual panels have significant contamination. This is especially true on higher roofs, where a small bird dropping may be almost impossible to see from the garden and a leaf can blend into the dark surface of the panel.
On an east-west installation, you may also be unable to see both slopes from the same place. One side may face the garden and the other the street, so it is easy to check one half of the array regularly and overlook the other.
When checking from the ground, look for bird droppings near chimneys and aerials, a duller appearance on one slope than the other, leaves around panel edges and new staining that wasn’t previously visible.
Using Your Monitoring Data
Depending on the equipment installed, you may be able to see the output of individual panels, groups of panels or complete strings.
If one panel or one slope is consistently producing less than expected under similar conditions, there may be a problem worth investigating. Monitoring data does not tell you exactly why a panel is underperforming, though. The cause could be dirt, shading, physical damage or an electrical fault. If panels have been cleaned and one section is still underperforming, the system should be assessed by an appropriately qualified solar professional.
Cleaning an East-West Array Safely
Cleaning a split array follows the same principles as cleaning any roof-mounted system, but the two slopes add some extra planning.
Purified Water and Soft Brushes
We use purified water and soft-bristle brushes to remove contaminants gently, with no harsh chemicals. Ordinary tap water contains dissolved minerals that can leave spots and streaks as it dries. Purified water has had those minerals removed, so the panels can be rinsed and left to dry naturally without the same spotting.
Pressure washing is not recommended. High-pressure water can damage seals and surfaces. Abrasive tools, harsh chemicals and walking on panels should also be avoided, as they can scratch or damage the surface and reduce performance.
Reaching Both Slopes
An east-west installation spans more than one roof elevation. Cleaning systems like this usually takes longer, because the work has to be carried out methodically across each section while maintaining safe access throughout.
Where conditions allow, a water-fed pole system means the panels can often be cleaned from ground level without anyone needing to walk on the roof. One slope may be straightforward to reach from the garden, while the other may face a street, a narrow side passage, a conservatory or an extension. Every property is assessed individually so the safest method can be chosen for each side. Our guide to reach and wash vs roof access explains how these decisions are made.
Our operatives are fully insured and IPAF and PASMA trained, and we have access equipment for all types of installations.
Timing the Clean Around the Sun
The best time to clean solar panels is when they are cool, usually early in the morning or late in the evening. Cleaning under direct sunlight should be avoided to prevent streaks and thermal stress.
On an east-west array, this needs a little more thought. East-facing panels can heat relatively early in the morning, while west-facing panels can remain exposed to direct sunshine later in the day and keep their heat into the evening. Different sections may need individual consideration, and two properties in the same street can have different ideal cleaning times. Professional cleaning is therefore based on the actual site conditions on the day rather than a fixed hour.
How Often Should an East-West Array Be Cleaned?
For domestic installations, we typically recommend cleaning every one to two years, depending on location. For commercial installations, we typically recommend a clean every six to twelve months. More frequent cleaning may be needed in areas with heavy dust, pollution or bird activity.
For a split array, it also makes sense to check both slopes rather than judging the whole system by the side you see most often. Nearby trees, busy roads, farmland, coastal salt and perching birds can all speed up dirt build-up, and across the South West we tailor our service to suit the location.
Keeping Both Sides of Your Array Working
East-west solar arrays spread generation across the day, and dirt can undermine that balance. Each slope collects contamination in its own way, and uneven soiling, particularly bird fouling near existing shade, can have a greater effect than a light, even layer of dust. Depending on how your system is wired, one heavily soiled panel may also hold back others.
If you would like your east-west array cleaned, our domestic solar panel cleaning service covers homes across Bath, Bristol and the South West, and our commercial solar panel cleaning service covers larger installations. Contact Solar Cleaning South West to request a no-obligation quote tailored to your system.